Adle heating problems

Adle heating problems

The following sections describe the most common problems with Adle Compact heating and hot water boilers and how to solve them.

Post content:

The heating does not start.

The electrical connector on the heater is loose

  • Check the electrical connectors and plug them in properly.

No voltage

  • Check if the voltage is more than 11V.

Faulty fuse

  • Check the 3A (230V) / 10A (12V) fuses and replace if necessary.

Red LED “Electronic control unit blocked” is lit

  • Switch off the heater, wait approximately 30 seconds and switch it on again
  • If none of the above advice has helped, contact Caravan Service.

The electric insert is not working

No 230V voltage

  • Make sure the voltage is 230V

No 12V voltage

  • Fuse blown. Check and replace the fuse.

Faulty relay in heater

  • Check that the relay is switching on. The relay can be heard to click gently. If you do not hear any click, contact the caravan service.

Overheating protection activated

  • Press the RESET button on the heater. The heating can only be switched on again when it has cooled down to a temperature of 10-20 degrees Celsius. Make sure the heater is well ventilated before switching the heater back on.
  • If none of the above advice has helped, contact Caravan Service.

The circulation pump won’t start

The switch on the room thermostat is off, in the “O” position

  • Switch the switch to the “I” position

Temperature is set lower than the current room temperature

  • This is not a fault of the circulator. If the temperature in the caravan drops below the set temperature, the circulator will automatically switch back on.

The electrical connector is loose

  • Check the electrical connectors on the circulation pump and plug them in properly.

No voltage

  • Check that the available voltage is 12V.
  • If none of the above advice has helped, contact the caravan service.